Welcome: Shenzhen Sanyi Technology Co., LTD.
Language: Chinese ∷  English

Din-rail power supply

  • DC 60w Din Rail power supply
  • DC 60w Din Rail power supply
DC 60w Din Rail power supplyDC 60w Din Rail power supply

DC 60w Din Rail power supply

  • Brand name: Sanyi Power
  • NIPUT:AC 100~240V 50/60Hz
  • OUTPUT:DC 24V 3A
  • Dimension: 88×72×59 mm(L*W*H)
  • Product description: Din Rail power supply for Automation equipment
  • INQUIRY

This rail power supply output constant current and constant voltage, digital tube display output current and voltage, low standby power consumption, high efficiency, high reliability, input and output can be connected in parallel

characteristic

01. International Universal AC input/ Full range

02. Built-in EMI filter

03.Short circuit/Over load Protections

04. Over voltage& temperature & Load Protections

05. 100% full load burn-in test

06.LED indicator for power

07.High efficiency, long life and high reliability

08.Can be customized according to user selection

09.Installation track:TS-35/7.5 & TS-35/


Product Specification

MODEL DR-60-5V DR-60-12V DR-60-15V DR-60-24V

Output DC Voltage 5V 12V 15V 24V

Rated Current 10A 5A 4A 3A

Current Range 0~10A 0~5A 0~4A 0~3A

Rated Power 50W 60W 60W 72W

Ripple & Noise Max(Note2) 80mVp-p 120mVp-p 120mVp-p 120mVp-p

Voltage Adj. Range ±15% ±15% ±15% ±15%

Voltage Tolerance(Note 3) ±2% ±1% ±1% ±1%

Line Regulation(Note 4) ±0.5% ±0.5% ±1% ±1%

LoadRegulation(Note 5) ±2.0% ±1% ±1% ±1%

Setup/Rise Time 1000ms,30ms/220Vac(Full load)
Hold up time(Typ.) 100ms/220Vac
Digital display output Switch Once/3S;  Accuracy 5%
Input Voltage Range 100~240VAC
Frequency Range 50/60Hz
Efficiency(Typ.) 83% 86% 87% 89%

Ac Current(Typ.) 1A/100Vac   0.4A/240Vac
Inrush Current(Typ.) Cold Start: 20A/220Vac
Leakage Current(Typ.) 0.4mA
Protection Over load protection 110%~120%

Protection type: Hiccup mode,recovers automatically after fault condition is removed
Over Voltage protection 110%~120%

Protection type: Hiccup mode,recovers automatically after fault condition is removed
Over-temperature protection Protected Mode: crystal internal contact temperature exceeds 140 ℃, turn off the output, when the temperature returns to normal automatic recovery
Environment Working Temp -10℃~60℃(Refer to "derating curve ")
Working Humidity 20~90%RH, non-condensing
Storage Temp/Humidity -30℃~75℃  10~98%RH, non-condensing
Temp Coefficient ±0.03% ℃(0~50℃)(+5V)
Vibration 10Min/1 cycle,period for 60min,each along X,Y,Z axes
Safety & EMC (Note 7) Safety Standards Note 6 GB4943, EN60950
Withstand Voltage I/P-O/P: 3KVAC   I/P-FG: 1.5KVAC O/P-FG: 1.5KVAC
Isolation Resistance I/P-O/P I/P-FG O/P-FG: 100M Ohms/500VDC/25℃/70%RH
EMI Conduction Radiation Compliance to: EN55022, EN61000-3-2,3. FCC part15, GB9254 class B, GB17625.1
EMS Immunity Compliance to: EN61000-4-2,3,4,5,6,8,11,light industry level, criteria A
Others MBTF ≥100000h.
DimensionPacking 88×72×59 mm(L*W*H) /0.25KG;100pcs/25Kg
Note 1.All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf &47uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.Load regulation measurement: from 0% to rated load of 100%.
6.In accordance with the requirements of GB4943.1 power applies only to an altitude of 2000 meters in the following areas and non-tropical climate conditions for safe use.
7.The power supply is considered part of the system components, to be with terminal equipment related to electromagnetic compatibility Relevant confirmation.
Design Drawing

unit:mm



CONTACT US

Contact: cherry

Phone: 18948217138

Tel: 0752-3838471

Email: cherry@szsanyi.cn

Add: #Yingfeng Industrial park, Economical and developing Zone, Sanhe, Huiyang, Huizhou , Guangdong Province, China

Scan the qr codeClose